Apicoectomies with retrograde instrumentation and retrofilling with low temperature thermoplasticized gutta-percha were performed in 29 teeth. Nineteen cases were clinically and radiographically evaluated within 12 to 41 months. The results showed a rate of 84.2% success, 10.5% failure and 5.2% incomplete healing. The use of retrograde instrumentation and retrofilling with low temperature thermoplasticized gutta-percha is suggested as a useful method in surgical procedures.